Heat Pump Systems

M-Series Heat Pumps - Indoor Units (Multi Zone)

MSZ

Overview

Slim, wall-mounted indoor units provide zone comfort control. INVERTER-driven compressors and electronic LEV's provide higher efficiency with controlled power usage. The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restored when power returns.

Ideal for applications such as bedrooms, home offices, living rooms, dining rooms, bonus rooms, basements, kitchens, guard houses, and more. Rated capacities range from 9,000 to 33,200 Btu/h.

 

  • Sleek, flat panel design
  • Hot-start technology
  • Quiet operation
  • i-see Sensor technology available
  • Enhanced filtration system available
  • Hand-held wireless remote; optional MHK1 backlit wall-mounted wireless remote controller
Model Specifications
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Cooling Rated Capacity 9000 Btu/h (2.64 kW) *1
Capacity Range 2800 - 9000 BTU/h (0.8 - 2.6 kW)
Total Input 580 < 160 - 650 > W (0.6 < 0.2 - 0.7 > kW)
Energy Efficiency SEER 26
Sensible Heat Factor 0.76
Heating at 47° F Rated Capacity 10900 Btu/h (3.2 kW) *2
Capacity Range 3000 - 18000 Btu/h (0.9 - 5.3 kW)
Total Input 710 (150 - 2250) W
HSPF (Region IV) 10
Heating at 17° F Maximum Capacity 12500 Btu/h (3.7 kW)
COP 3.02 Btu/Btu
Heating at 5° F Maximum Capacity 10900 Btu/h (4.8 kW)
Minimum Circuit Ampacity MCA 1 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
Airflow Cooling : DRY 162-226-339-381 CFM (4-6-9-10 m³/min)
Cooling : WET 144-202-307-343 CFM (4-6-9-10 m³/min)
Heating : WET 166-240-367-381 CFM (5-7-10-11 m³/min)
Sound Pressure Level Cooling 22-31-39-42 dB(A)
Heating 22-31-40-42 dB(A)
Dimensions H x W x D Height 11-5/8 Inches (295 mm)
Width 31-3/8 Inches (799 mm)
Depth 10-1/8 Inches (257 mm)
Net Weight 27 Lbs. (12 kg)
Refrigerant Pipe Size O.D. Gas (Low Pressure) 3/8 Inch (9.52 mm)
Liquid (High Pressure) 1/4 Inch (6.35 mm)
Field Drainpipe Size O.D. 5/8 Inch (15.88 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 90°F (32°C) DB , 73°F (23°C) WB
Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Heating - Maximum - DB , WB 80°F (27°C) DB, 67°F (19°C) WB
Heating - Minimum - DB , WB 70°F (21°C) DB, 60°F (16°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Cooling- Minimum - DB , WB 14°F (-10°C) DB
Heating - Maximum - DB , WB 75°F (24°C) DB, 65°F (18°C) WB
Heating - Minimum - DB , WB -13°F (-25°C) DB, -15°F (-26°C) WB