Cooling-only Systems

P-Series AC

PLA

Overview

Ceiling-recessed ductless air conditioners - 33x33". Rated capacity range 12,000 - 42,000 Btu/h.

  • Branch duct capability
  • Multiple controller options
  • Built-in drain lift mechanism for condensate removal; lifts to 33-7/16"
  • Wide air flow pattern for better air distribution
  • Auto wave airflow in heating mode—unit independently cycles
  • Independent vane adjustment
  • Automatic fan speed control
  • Self-check function—integrated diagnostics
  • Advanced microprocessor control
  • Limited warranty: five years on parts/defects, seven years on compressors
Model Specifications
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Cooling Rated Capacity 12000 Btu/h (3.52 kW) *1
Capacity Range 6000 - 12000 BTU/h (1.8 - 3.5 kW)
Total Input 1260 W (1.300 kW)
Energy Efficiency SEER 13.5
Sensible Heat Factor 0.84
Minimum Circuit Ampacity MCA 1 Ampere
Maximum fuse size (time delay) MOCP 15 Ampere
Recommended Fuse/Breaker Size 15 Ampere
Refrigerant Type R410A
External Static Pressure 0 (direct blow)
Airflow Cooling : DRY 390-420-460-530 CFM (11-12-13-15 m³/min)
Cooling : WET 350-390-420-490 CFM (10-11-12-14 m³/min)
Sound Pressure Level Cooling 27-28-29-31 dB(A)
Dimensions H x W x D Height UNIT : 258 Inches (10-3/16 mm) ; PANEL : 35 Inches (1-3/8 mm)
Width UNIT : 840 Inches (33-1/16 mm) PANEL : 950 Inches (37-3/8 mm)
Depth UNIT : 840 Inches (33-1/16 mm) PANEL : 950 Inches (37-3/8 mm)
Net Weight UNIT : 22 (49 kg) PANEL: 6 (13 kg)
Field Drainpipe Size O.D. 1-1/4 Inches (32 mm)
Refrigerant Piping Connection Method Indoor / Outdoor Flared / Flared
Operation Conditions - Indoor Intake Air Temperature Cooling - Maximum - DB , WB 95°F (35°C) DB, 71°F (22°C) WB
Cooling - Minimum - DB , WB 67°F (19°C) DB , 57°F (14°C) WB
Operation Conditions - Outdoor Intake Air Temperature Cooling - Maximum - DB , WB 115°F (46°C) DB
Cooling- Minimum - DB , WB 0°F** (-18°C) DB